A P-3 embed plate is set near the edge of a precast panel with a minimum 6 inch vertical edge clearance. Number 4 U-bars extend 48 inches at each HSA row, anchored behind the embed plate. Number 4 vertical reinforcing bars at 7 feet 0 inches tie into the panel grid as specified on the panel elevation.
48" 6" MIN VERT. REINFORCING SEE PANEL ELEVATION #4 x 7'-0" P-3 EMBED EDGE OF TIPS PANEL #4 U-BARS AT EACH HSA ROW EXTEND 48"