An angle measuring three inches by three inches by three-sixteenths of an inch is sized to the width of the opening plus three feet typical at isolated openings in non-composite metal deck. The angle is secured with a one-eighth-inch one-spot weld at each flute. Metal deck manufacturer closure is provided. Openings less than six inches by six inches require no framing and openings must maintain a twenty-inch minimum clearance between them.
1/8 1 SPOT WELD EA. FLUTE NOTES: 1. OPENINGS LESS THAN 6"x6" REQUIRE NO FRAMING. 2. OPENINGS SHALL HAVE 20" MINIMUM CLEARANCE BETWEEN THEM. 3/16 TYP. 16" MAX. S D F dfg dfg CLOSURE BY MTL DECK MFR L3x3x3/16 x WIDTH OF OPN'G +3'-0" TYPICAL AT ISOLATED OPENINGS IN NON-COMPOSITE