A cold-formed steel stud parapet wall is supported by a structural steel beam with a metal roof deck. The parapet is constructed using six-inch by eighteen-gauge metal studs spaced at sixteen inches on center, tied into a bottom six-inch by sixteen-gauge continuous track secured with number ten self-tapping screws at eight inches on center. Diagonal metal stud braces measuring six inches by sixteen-gauge connect the parapet to the metal roof deck at sixteen inches on center. A continuous forty-three mil track fastens to the deck using two number ten self-tapping screws at eight inches on center and two number ten self-tapping screws to the brace. The supporting steel beam features a web stiffener and is sized per structural plans.
43mil (18GA) x CONT TRACK WITH (2) #10 STS TO DECK AT 8" O.C. AND (2) #10 STS TO BRACE METAL ROOF DECK STEEL BEAM, SEE PLAN 6"x16GA (600S125-54) xCONT TRACK METAL STUD BRACE TO MATCH STUD WALL PARAPET AT 16" O.C. EXTERIOR SHEATHING, SEE ARCH 6"x18GA (600S162-43) METAL STUDS AT 16" O.C. 6"x16GA (600T125-54 xCONT TRACK WITH #10 STS AT 8" O.C. 24" MAX STEEL BEAM, SEE PLAN STEEL BEAM, SEE PLAN BEAM WEB STIFFENER 5"