A channel section frames into the flange of a wide flange steel column with a maximum one inch clearance dimension indicated at the top flange. Three-sixteenth-inch fillet welds secure the connection typically along the web and flange interfaces, with field weld symbols indicated by triangular flags. A clearance gap of three-sixteenths is maintained typically at the connection interface.