A concrete slab on grade transitions into an edge step and thickened footing. The slab features slab on grade reinforcement per plan with a top of slab elevation marker. The thickened edge includes #4 reinforcing bars spaced at twelve inches on center and a minimum one-foot-zero-inch vertical depth. Additional variable dimensions and lap splice lengths designated as Lsb are provided for the slab and footing reinforcement.
SOG PER PLAN EL PER PLAN TOP OF SOG 1' - 0" 12" 1 1 1 /2 " #4 @ 12" #4 @ 12" MIN 1' - 0" 1 1 1 7 5 /8 " SOG REINF PER PLAN SOG REINF PER PLAN VARIES TBD" MAX NOTE 1 VARIES TBD" MAX NOTE 1 MIN 4" Lsb Lsb SOG PER PLAN EL PER PLAN TOP OF SOG 1' - 0" 12" 11 1/2" #4 @ 12" #4 @ 12" MIN 1' - 0" 1 1 17 5/8" SOG REINF PER PLAN SOG REINF PER PLAN VARIES TBD" MAX NOTE 1 VARIES TBD" MAX NOTE 1 MIN 4" Lsb Lsb