A steel joist girder frames into a tilt-up concrete wall panel joint, utilizing embedded plates anchored into the concrete panels. The bottom chord connects to a stabilizer plate, left unwelded per drawing notes. Wood nailers and panel reinforcing are omitted from the view for clarity. A three-inch typical dimension spaces the concrete wall panels.
A. DO NOT WELD BOTTOM CHORD TO STABILIZER PLATE B. WOOD NAILER NOT SHOWN FOR CLARITY C. PANEL REINFORCING NOT SHOWN FOR CLARITY PLAN VIEW AT PANEL JOINT CONDITION 2 1 1 3" TYP.