A running bay pan track opening within a concrete assembly utilizes 16 millimeter diameter by 200 millimeter long Nelson studs spaced at 250 millimeters on center, welded to bent plates for embedment. The pit opening spans 1070 millimeters clear with a 1040 millimeter clear opening and a maximum extension of 1168 millimeters. Edge conditions incorporate bent plate 8 and bent plate 6 with a depth to suit, alongside L76x76x6.4 structural angles.
1040 CLR 1168 MAX EXTENTION 64 64 75 BENT PL 6 DEPTH TO SUIT L76x76x6.4 1070 PIT OPENING BENT PL 8 113 16Ø 200 LG NELSON STUDS @ 250 O/C 300