The drawing illustrates isometric and sectional details for installing waterstops in reinforced concrete structures. It includes details for wall pour joints, slab section joints, and both sleeved and cast-in-place pipe penetrations. Reinforcing steel placement and waterstop continuity requirements are clearly annotated throughout the assemblies.
Text on the drawing
T.O. GRADE EL.: REF. DWGS BY OTHERS INSTALL WATERSTOP INSIDE OF OUTERMOST REINFORCING STEEL REINFORCING STEEL INSTALL WATERSTOP AT ALL FOOTING/ WALL JOINTS, R.A.D. INSTALL WATERSTOP AT ALL SLAB POUR JOINTS AND CONNECT WITH WALL JOINT INSTALLATION TO FORM CONTINUOUS WATERSTOP, R.A.D. NON-SHRINK GROUT INSTALL WATERSTOP AT ALL WALL POUR JOINTS, R.A.D. WATERSTOP REINFORCED SLAB SLAB SECTION JOINT CONCRETE CAST-IN-PLACE PENETRATION PIPE SLEEVE, BY OTHERS PIPE, BY OTHERS WATERSTOP SLEEVED PENETRATION CONCRETE
Members view this detail in full resolution, download the CAD files (SVG, PDF), and open any detail in the built-in CAD editor to edit and export DXF or DWG.