A gravity column anchor bolt connection is anchored into concrete. The assembly utilizes a 1 1/4 inch diameter anchor bolt with a leveling nut and a hooked embedment of one foot with a four-inch hook length. A base plate of thickness T is specified per schedule and sits above a maximum three-inch layer of non-shrink grout. Washers are provided at oversized holes under the top nut assembly.
1 1/4"Ø A.B. W/ LEVELING NUT, TYP. PROVIDE MIN. WASHER AT OVERSIZED HOLES 3" MAX. NON-SHRINK GROUT BASE PL THICKNESS 'T' - SEE SCHEDULE 1'-0" EMBEDMENT 7 S-155511 4"