Hollow structural section members feature drilled weep holes at designated low points to prevent internal moisture accumulation. End conditions incorporate a half-circle weep hole with a three-eighths-inch radius unless noted otherwise, positioned adjacent to an end or fitted plate left unwelded within the weep hole region. Longitudinal members receive three-eighths-inch diameter weep holes drilled perpendicular to the member face along the centerline or low point. All weep holes must be installed per project specifications and structural drawings.
A-A A-A WEEP HOLE AT MEMBER END R=3/8" UNO HSS MEMBER HALF CIRCLE WEEP HOLE. LOCATE AT MEMBER LOWPOINT WHERE MEMBER IS SLOPED END OR FITTED PL ELEVATION HSS GIRT MEMBER 3/8"Ø WEEP HOLE UNO. LOCATED ALONG MEMBER LONGITUDINAL CENTERLINE TYPICALLY OR AT MEMBER LOW POINT IF MEMBER IS ROTATED ABOUT ITS LONGITUDINAL AXIS SECTION A-A WEEP HOLE ALONG MEMBER LENGTH NOTES: 1. DESIGNATION ON DETAILS. 2. WEEP HOLES ARE TO BE DRILLED PERPENDICULAR TO MEMBER FACE. HSS GIRT MEMBER CL WEEP HOLE REGION DO NOT WELD WITHIN A