A two-foot-tall cantilevered cold-formed steel pony wall is framed with HSS 3x3x1/4 hollow structural sections spaced at four inches on center, capped with a 1/4-inch plate. The structural steel posts weld to a 1/2-inch by 4-inch by 9-inch base plate with a 3/16-inch fillet weld. The base plate anchors into the concrete slab edge using two 1/2-inch diameter by 4-1/2-inch wedge head screws spaced at seven inches on center. Two number 4 hairpin reinforcing bars embed within the concrete slab adjacent to the anchorage.
COLD-FORMED PONY WALL PER CFS DESIGNER 3/16 2'-0" CAP PL1/4 HSS3x3x1/4 @ 4" OC PL1/2x4x0'-9" W/ (2) 1/2"Øx4 1/2" WHS @ 7" OC (2) #4 HAIR PINS