The framing connection for a hangar door soffit runs between grid lines A and B. A horizontal steel beam connects to framing members with a three-eighths-inch by three-inch by six-and-a-half-inch plate secured by two three-quarter-inch diameter A325-SC-OVS bolts spaced at three inches on center, supplemented by welded connections. Additional support is provided by L4x4 angles and a three-eighths-inch by five-and-a-half-inch by six-and-a-half-inch connection plate with matching bolt assemblies. Wall panels, soffit panels, and hangar doors interface with the assembly per architectural drawings, while bottom of steel elevation is established at 165'-2".
A B 2'-10" 1'-2" * 14'-10" * GIRT PER EL TYP BOS EL 165'-2" 1/4 1/4 PL3/8X3X0'-6 1/2" W/ (2) 3/4" DIA A325-SC-OVS BOLTS AT 3" OC L4X4 PER NOTE 8/S-160 S-160 1/4 1/4 1/4 3 NS&FS CJP UT HSS SOFFIT FRMG PER PLAN L4X4X1/4 L4X4X1/4 PL3/8X5 1/2X0'-6 1/2" W/ (2) 3/4" DIA A325-SC-OVS BOLTS AT 3" OC WALL PANEL PER ARCH DWG A-351 - A-353 HANGAR DOOR PER ARCH DWG A-422 TYP SOFFIT PANEL PER ARCH DWG A-351 - A-353 CONTINUE THIS TUBE FRAME LINE THROUGH ENTIRE SOFFIT BM PER PLAN TYP