Two concrete curb profiles are cast on top of a concrete-filled metal deck slab, distinguished by widths less than or equal to eight inches and widths greater than eight inches. Reinforcement consists of number three dowels spaced at twenty-four inches on center, featuring a 180-degree bend at the top and a 90-degree hook at the bottom for anchorage into the slab. Narrow curbs incorporate a single continuous number three bar at the center, while wider curbs utilize number three bars at twelve inches on center each way. Both conditions maintain a three-quarter-inch clear cover and a maximum height of six inches with a one-half-inch typical top radius.
1/2" RADIUS, TYP. #3 @ 12" O.C. EA. WAY 1/2" RADIUS, TYP. #3 DOWEL W/ 180° BEND AT TOP & 90° HOOK AT BOTTOM @ 24" O.C. E.W. #3 DOWEL W/ 180° BEND AT TOP & 90° HOOK AT BOTTOM @ 24" O.C. #3 CONT. AT CENTER OF CURB WIDTH GREATER THAN 8" WIDTH LESS THAN OR EQUAL TO 8" 3/4" CLR. 6" MAX. 3/4" CLR. 6" MAX.
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.