A structural steel column is welded to a steel base plate secured by eight high-strength anchor bolts with a diameter of one inch. The base plate rests above a two-and-a-half-inch maximum layer of non-shrink grout placed over a reinforced concrete foundation. The embedded anchor bolts extend vertically down into the concrete footing with standard leveling nuts.
1"Ø H.S. ANCHOR BOLT, TYP. (8 TOTAL) 2 1/2" MAX. NON-SHRINK GROUT
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.