Banded post-tensioned tendons within a flat plate concrete slab feature a typical center of gravity profile following a smooth parabolic curve across supports, with heights dimensioned relative to the reference plan. Additional tendons are included at specific locations as indicated on the plan. A lower distributed tendon group is positioned at the centerline of the column and tied to the underside of the banded tendons with a minimum of two strands.
REF. PLAN TYP. HEIGHT C.G. OF TENDON REF. PLAN TYP. HEIGHT C.G. OF TENDON C.G. OF BANDED TENDONS IN SMOOTH PARABOLIC CURVE TYP. COLUMN OR WALL BELOW ADDED TENDONS WHERE OCCURS REF. PLAN EQ EQ LOWER ONE DISTRIBUTED TENDON GROUP AT CENTRELINE OF COLUMN AND TIE TO UNDERSIDE OF BANDED TENDONS (2 STRANDS MINIMUM) TYP-P-105 TYPICAL FLAT PLATE BANDED TENDON PROFILE