Concrete tilt-up wall panels meet at building corners in either mitered or butt joint configurations. The miter joint features a mitered corner with a three-quarter-inch maximum gap and sealant detailed per architectural drawings, requiring panel thickening where indicated. The butt joint connects the panels perpendicularly with a rounded edge profile and a three-quarter-inch maximum joint width filled with sealant.
1" 1" PANEL DIM. PANEL DIM. CONC. TILT-UP WALL PANEL THICKEN PANEL WHERE OCCURS SEALANT (SEE ARCH.) MITER JOINT PANEL DIM. SEALANT (SEE ARCH.) BUTT JOINT NOTE: MITER JOINT ONLY WHERE OCCURS PANEL DIM. CONC. TILT-UP WALL PANEL 3/4" MAX 3/4" MAX