This structural section details a concrete tunnel assembly situated between the basement level at elevation 3'-9 5/8" and the apron level at 17'-9 5/8". The concrete walls and slab thicknesses are sized per the tunnel schedule, featuring a clear width and height coordinated with the structural plans. A two-foot-six-inch wide by two-foot-deep concrete beam supports the upper slab system on cast-in-place concrete columns. Drainage board is applied to the exterior face of the concrete wall below a design water table established at elevation plus eight feet relative to NAVD 88. Wall reinforcement is omitted for clarity and referenced to the tunnel schedule on drawing 13/S5.02.
01 - APRON LEVEL 17' - 9 5/8" 00 - BASEMENT LEVEL 3' - 9 5/8" CONC WALL SEE SCHEDULE TYP CONC THICKNESS SEE SCHEDULE CONC SLAB, SEE SCHEDULE SEE PLAN AND SCHEDULE CLEAR WIDTH TUNNEL HEIGHT - SEE SCHED 2'-6" WIDE x2'-0" DEEP CONCRETE BEAM 13/S5.02 DESIGN WATER TABLE +8'-0" (NAVD 88) DRAINAGE BOARD NOTE: 1. WALL REINFORCEMENT, NOT SHOWN FOR CLARITY, REFER TO TUNNEL SCHEDULE FOR REINFORCEMENT.