The open web steel joist rests on a column cap plate, with the joist seat depth specified as seven and one-half inches. A one-quarter inch fillet weld is applied to the LH series joist seat. The column is fitted with three-eighths inch by six inch by six inch stabilizer plates for K series joists, or three-quarter inch by six inch by six inch plates for LH series joists, each featuring a thirteen-sixteenths inch diameter hole. These stabilizer plates are attached to the column with three-sixteenths inch fillet welds on both sides. The joist is left unwelded to the stabilizer plate, and bolt locations must be coordinated between the joist manufacturer and the steel fabricator.
CAP PL. ROOF DECK, SEE PLAN DBE SEE PLAN 1/8 2 1/2" 1/4 @ LH SERIES 1/2" SEAT 7 1/2" GIRDER * SEE PLAN SEE 2/S302