Steel column base plate details show three column types with varying anchor bolt configurations and plate dimensions designated as Type T1, Type T2, and Type T3. The base plates feature a one-quarter-inch fillet weld to the face of flats at the structural steel tubes. A two-inch thick non-shrink grout layer sits beneath the base plate over the concrete foundation. Anchor rods extend a minimum of nine inches into the concrete support with hooked ends and typical three-inch edge clearances. Sizing parameters define dimension G as the workable gage of the supporting beam per AISC Manual Table 1-1 or three times the bolt diameter, and dimension D as the column width plus one inch or G plus three inches.
TUBE/PIPE COLUMN TYPE T2 1 1/2" TYP 1 1/2" TYP 1/2" TYP 1/2" TYP 1 1/2" TYP B N B N 1/4 WELD FACE OF FLATS AT TUBES TYPE T1 1 1/2" 1 1/2" TYP D TYPE T3 G 1/2" TYP EMBED 9" MIN 3" TYP G = WORKABLE GAGE OF SUPPORTING BEAM PER AISC MANUAL TABLE 1-1 OR 3 x BOLT DIAMETER, WHICHEVER IS GREATEST D = COLUMN WIDTH +1", OR G + 3", WHICHEVER IS GREATEST 2" NON-SHRINK GROUT
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.