Cross-laminated timber roof panels bear onto a timber ridge beam featuring an angular cut at the top to accommodate the roof slope, eliminating the need for sacrificial lamination. The panels meet at the ridge with a one-eighth-inch maximum gap and a five-inch maximum spacing. Connection is secured using SDWS22 structural wood screws at two feet on center typical for each panel along the ridge, providing a minimum two-and-a-half-inch embedment into the ridge beam.
NOTES: 1. SEE "CLT PANEL CONN AT BUILDING OVERHANGS" FOR FASTNER 1/8" MAX GAP SDWS22 AT 2'-0" O.C, TYP FOR EA PANEL ALONG RIDGE. PROVIDE MIN 2 1/2" EMBED INTO RIDGE BEAM RIDGE BEAM. PROVIDE ANGULAR CUT AT TOP OF BEAM TO ACCOMMODATE ROOF SLOPE, NO SACRIFICIAL LAMINATION REQUIRED. CLT PANEL MAX 5"