A wide-flange beam frames into another wide-flange beam at a step using a full-height shear plate sized per plan. A full-height stiffener plate is provided on the supporting beam web per detail 2/S-520. Additional framing information is coordinated per plan and detail 6/S-520.
Wx BEAM PER PLAN FULL HT SHEAR PL Wx BEAM PER PLAN NOTE: FOR BALANCE OF INFO NOT SHOWN, SEE PLAN PER 6 S-520 FULL HT STIFF PL PER 2 S-520
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.