Cold-formed metal framing at a door opening along a slab edge consists of a bottom track fastened to the concrete floor and framing studs sized per schedule. A king stud is positioned at the frame opening with additional fasteners specified by the schedule. Fastener spacing follows typical dimensions of two inches and three inches minimum. The bottom track terminates at the face of opening centerline.
SLAB EDGE KING STUD PER SCHED. CTL FLOOR BOT. TRACK PER SCHED., 3/s-702 ADD'L FASTENER PER KING STUD SCHED. STUD PER SCHED. 3" TYP. 2" TYP. 3" MIN. F.O. OPNG (END OF BOT. TRACK FOR DOOR CONDITION)