Boundary element reinforcement for a reinforced concrete shear wall incorporates Grade 80 A706 number five ties spaced at four inches on center maximum to satisfy ACI 318-14 section 18.10.6.4 c. The transverse reinforcement consists of continuous rebar hoops or ties as shown, supplementing the typical wall reinforcement indicated on the shear wall elevation. The wall thickness is sized per elevation with equal spacing distributed across the boundary zone.
SEE ELEV WALL THK TYPICAL WALL REINF, SEE SHEARWALL ELEV . EQ EQ GR80 A706 #5@4" OC MAX TIES THAT SATISFY ACI318-14 18.10.6.4 c, MAY BE CONT REBAR HOOP OR TIES AS SHOWN REINF AS SHOWN ON SHEARWALL ELEVATION TYP 6" C 14 BARS TYP 4"