A kick plate connects stair stringers in an auditorium seating area. The assembly incorporates an 1/8-inch gap at the joint between adjacent sections, with centerline-to-centerline dimensions establishing the stringer layout. Five-eighths-inch round head tension-control bolts secure the plate, equally spaced across the connection. The kick plate height is sized per the architectural arch geometry, maintaining a standard 2-inch typical edge clearance from the stringer centerline.
AT JOINT 1/8" GAP 2" TYP CL OF STRINGER CL OF STRINGER CL OF STRINGER 5/8" ROUND HEAD T/C BOLTS, EQUALLY SPACED AS SHOWN ARCH PER