A concrete slab on grade bears against a concrete tilt-up panel using number four by two-foot six-inch dowels at eighteen inches on center epoxied into the concrete tilt-up panel with one and a half inch minimum cover. An alternate option provides number four by two-foot six-inch dowels at eighteen inches on center threaded one end with one-half inch diameter heavy stud anchors.
1 1/2" COVER (MIN.) OPTION #2 CONC SLAB ON GRADE #4 x 2'-6" DOWEL @ 18" O.C. THREADED ONE END CONC TILT-UP PANEL 1/2" DIA. HSA. #4 x 2'-6" DOWEL @ 18" O.C. EPOXIED INTO CONC TILT-UP PANEL A 2. <7 ■ A A 24 O A 222/ <1 W W