Post-tensioned concrete slab and concrete girder assembly featuring distributed post-tensioning tendons and temperature tendons sized per plan. Chairs and support bars are positioned on both sides of the beam to maintain tendon profiles within the slab. The concrete slab spans across the integral concrete girder with reinforcement sized per structural layout.
AT CONCRETE GIRDERS PER PLAN PER PLAN P-T TEMPERATURE TENDON, PER PLAN CHAIRS & SUPPORT BARS BOTH SIDE OF BEAM CONC GIRDER PER PLAN P-T CONC SLAB PER PLAN DIST P-T TENDON PER PLAN, TYP T/SLAB PER PLAN