A wide-flange steel beam supports a metal deck transition, featuring shear studs at the low flute of the perpendicular deck. A 0.76 mm galvanized closure angle measuring 200 mm long is installed over each high flute per manufacturer published recommendations. Clearances are specified at 25 mm minimum, with edge distances of 50 mm minimum at a single row of studs and 125 mm minimum at a double row of studs.
50 MIN AT SINGLE ROW OF STUDS, 125 MIN AT DOUBLE ROW OF STUDS PROVIDE 0.76 mm GALV CLOSURE ANGLE 200 LG OVER EACH HIGH FLUTE, INSTALL PER MFR PUBLISHED RECOMENDATIONS STUDS TO BE LOCATED AT LOW FLUTE OF PERPENDICULAR DECK 25 MIN