A continuous 3x top chord nailer, matching the width of the steel joist chord, is fastened through the top chord of the steel joist with two #14 wood screws at 24 inches on center. A wood purlin is supported by the steel joist using a Simpson HFN hanger, attached per the manufacturer's recommendations. Roof sheathing is installed over the top of the purlins and nailer assembly as specified per plan.
Text on the drawing
STEEL JOIST PER PLAN (TYP.) WOOD PURLIN PER PLAN SIMPSON HFN HANGER - ATTACH PER MANUF. RECOM. (TYP.) CONT. 3x TOP CHORD NAILER MATCHING JOIST CHORD WIDTH - FASTEN THRU TOP CHORD OF JOIST W/ (2) #14 WOOD SCREWS @ 24" SPA. (TYP.) ROOF SHEATHING PER PLAN