A hollow structural section post mounts to structural steel framing beams using a base plate welded with three-eighths inch fillets top and bottom. Full-height stiffener plates are provided on each side of the supporting beam web at intersecting members or kickers as indicated on plan. A parallel kicker brace frames into the support assembly, while offset configurations utilize a Grade 50 flange extension plate connected via a one-inch complete joint penetration weld to the flange. The hollow structural section post size matches the member specified above up to an eight-foot maximum height.
3/8 3/8 T&B PL1 TYP 3" HSS POST PER PLAN HSS TO MATCH POST SIZE ABOVE 8'-0" MAX BEAM PARALLEL KICKER PER N/S5.01 WHERE INDICATED ON PLAN BEAM PERPENDICULAR BEAM OFFSET FULL-HEIGHT STIFF PL AT INTERSECTING BEAM OR KICKER PER L/S5.01 FULL-HEIGHT STIFF PL EA SIDE PER L/S5.01 KICKER PER N/S5.01 WHERE INDICATED ON PLAN FULL-HEIGHT STIFF PL EA SIDE PER L/S5.01 GR 50 FLANGE EXTENSION PL x 0'-9" 1" CJP EXTENSION PL TO FLG