A hollow structural section post is supported by a wide-flange W10 beam sized per plan. A 3/8-inch by 8-1/2-inch by 12-inch connection plate is welded to the HSS post with a 5/16-inch fillet weld. The plate is secured to the supporting beam flange using four 3/4-inch diameter bolts.
5/16 HSS POST 5 1/2" 1 1/2" TYP. W10 SEE PLAN 3/8X8.5X12" (4) 3/4" Ø BOLTS PLAN ELEVATION S7.100 1" = 1'-0" 20 TYP. SCREEN WALL BEAM TO POST CONNECTION