A double brace connection ties into a central column supported by a reinforced concrete footing. Dual diagonal braces attach to gusset plates on either side of the column, transferring lateral loads into the foundation. Continuous eighteen-millimeter Dywidag bars fifty-seven millimeters in diameter run through each side of the concrete member. The brace forces are determined per the buckling-restrained brace schedule, allocating fifty percent of the total force to each side of the column.
TYP 300 DOUBLE BRACE 5200 18M (57 DIA) DYWIDAG BARS ES, 5200 CONT REFER TO BRB SCHEDULE FOR BRACE FORCE 50% OF FORCE EA SIDE OF COLUMN 5200 95 MIN