This structural plan detail shows a two-and-a-half-foot thick reinforced concrete pier cap and column centered on intersecting column and pier cap centerlines. The square concrete section measures three feet by three feet, with symmetrical dimensions of one foot six inches from the centerlines to the outer faces. Reinforcement consists of six number six bars placed in both the bottom and each way layers, unless noted otherwise. The assembly maintains a typical layout centered on the specified structural axes.
2'-6" THICK PIER CAP & COLUMN UNO (6)#6(B) EW PIER CAP & COLUMN UNO 1' - 6" 1' - 6" 3' - 0" 1' - 6" 1' - 6" 3' - 0"