Slab reinforcement terminates at a two-foot-six-inch wide pour strip adjacent to a three-foot-six-inch wide by eighteen-inch deep continuous footing. Number four dowels are spaced at eighteen inches on center typically along the line unless noted otherwise. Panel dowels span from the panel to the slab at twenty-four inches on center with a minimum of three per pier. Slab reinforcement terminates at the pour strip per the indicated typical condition.
1 SD.2 TYP U.N.O. 3'-6"W X18"D CONT. FOOTING 2'-6" WIDE POUR STRIP PANEL DOWELS @ 24" O.C. FROM PANEL TO SLAB (MIN 3 PER PIER) TYP. @ THIS LINE U.N.O. TERMINATE SLAB REINF. AT POUR STRIP TYP. @ THIS LINE #4 DOWELS @ 18" O.C. TYP. @ THIS LINE U.N.O. F2 C1 F2 C1 F3 - F3 - F3 -
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.
Start membership