A concrete slab on metal deck extends past a W8x10 steel beam to form a cantilevered overhang with a maximum dimension of three feet. The slab has a minimum depth of five inches with one-inch clear cover over slab reinforcing. A continuous L4x3x3/8 angle provides edge support, tied with 5/8-inch diameter by three-foot long dowel bars and additional number five bars with skewed standard hooks lapped into the assembly. Shoring is required beneath the slab until the concrete achieves seventy-five percent of its design strength. A second W8x10 steel beam supports the inner span of the deck transition.
1" CLR. SLAB DEPTH 5" MIN. OVERHANG 2x OVERHANG 1/8 1-12 5/8"ø x3'-0" D2L CONC. SLAB ON METAL DECK. ORIENTATION PARALLEL TO EDGE 3'-0" MAX, S.A.D. EDGE FORM BY OTHER. SHORE UNTIL CONCRETE ACHIEVES 75% OF DESIGN STRENGTH SLAB REINF. L4"x3"x3/8" CONT. (LLV) ADD #5 W/ SKEWED STD. HOOK TO LAP W/ D2L W8x10 AT DECK TRANSITION, (MAY NOT BE SHOWN ON PLANS)