An HSS cladding post connects to a wide flange steel beam using a WT6x17.5 shape and a half-inch thick plate centered on the WT section. A three-eighths inch bent plate connects the HSS cladding post, with fillet welds specified at both sides. An additional HSS post is integrated as shown in plan, supported by the steel framing. All member sizes and locations are coordinated per the structural framing plans.
G 1'-1" HSS POST SEE PLAN HSS CLADDING POST SEE PLAN SECTION AT RIGHT 7'-8" PLAN F 1" 1" PL1/2x8x8 CTRD ON WT WT6x17.5 3/16 4 BOTH SIDES 3/16 3/8" BENT PL SEE 18/S-565 4 1/4" T/STEEL SEE PLAN HSS CLADDING POST SEE PLAN 3/8" BENT PL WT6x17.5 WF BEAM SEE PLAN HSS POST SEE PLAN 18 S-565 SECTION