A mass plywood panel stair tread spans between structural steel stringers sized per plan and is anchored using L6x3x5/16 by zero-foot four-and-one-half-inch long angles. Two quarter-inch diameter by two-and-one-half-inch long screws spaced at three inches on center secure the angle to the stair tread. A three-sixteenths-inch fillet weld connects the angle to the stair stringer. Guardrail posts provided by others mount directly to the stair tread using a minimum of four five-sixteenths-inch diameter countersunk through-bolts.
GUARDRAIL POST CONNECTION PER OTHERS (MIN (4) 5/16"Ø THRU BOLTS C'SUNK) GUARDRAIL POST PER OTHERS MPP STAIR TREAD PER OTHERS L6X3X5/16 X 0'-4 1/2" LLV W/ (2) 1/4"Ø X 2 1/2" SCREWS @ 3"OC TO STAIR TREAD 3/16 STRINGER PER PLAN