A foundation base drainage assembly is installed between steel soldier piles spaced equally per plan. A three-inch diameter perforated pipe sits within a gravel pocket atop drainboard and waterproofing panels applied to the concrete slab. A one-eighth inch thick by three-quarter inch deep sawcut filled with silicone is positioned in the slab between the pile locations. Lap splices are executed using the non-contact lap splice method with a minimum vertical spacing of eighteen inches on center. Lagging, waterproofing, and drainage are omitted in the alternate view for clarity.
EQ. EQ. NOTES: 1. LAGGING, WATERPROOFING AND DRAINAGE ARE NOT SHOWN FOR CLARITY. 2. STEEL SOLDIER PILES SHOWN, APPLICABLE TO PIERS. 3. SINGLE CURTAIN SHOWN, DOUBLE CURTAIN SIM. 1/8"THKx3/4" DEEP SAWCUT. FILL W/ SILICON PILE SPACING - SEE PLAN 2'-0" 3"Ø PERF. PIPE 3"Ø OUTLE PIPE GRAVEL POCKET WATERPROOFING PANELS DRAINBOARD EQ EQ NOTES: 1. LAGGING NOT SHOWN FOR CLARITY. 2. REFER TO WATERPROOFING DETAILS. 3. PIER SOLDIER PILES SHOWN, APPLICABLE TO STEEL PILES. 5 SS500 6 SS500 LAP SPLICES SHALL BE BY THE NON-CONTACT LAP SPLICE METHOD WITH A MIN. VERTICAL SPACING BETWEEN LAPS SHOULD OCCUR NO CLOSER THAN 18" O.C.