A gym canopy framing assembly connects to a primary support column. A hollow structural section beam frames into the column via a welded beam-to-column connection sized per plan. The outer edge features an HSS18X fascia member welded to a three-quarter-inch thick cap plate with a complete joint penetration weld. Intermediate HSS6X and HSS12X framing members tie into the assembly with specific connection details referenced to other sheets. A closure plate seals the edge condition typical of the canopy perimeter.
GL HSS TO CAP PL, CJP HSS18X PER PLAN CLOSURE PLATE PER 03 2-S6.13 TYP HSS TO HSS CONNECTION PER 03 2-S6.15 HSS6X PER PLAN HSS6X PER PLAN HSS12X PER PLAN 3/4" THK CAP PL COLUMN PER PLAN HSS BEAM TO COLUMN CONNECTION PER PLAN