These details show vertical reinforcing placement conditions relative to steel deck down flutes, separating alignments where reinforcing aligns with the down flute from those where it does not. Number four continuous rebar and number four bars at twelve inches on center are detailed with specific clearances including three-quarter-inch and two-and-a-quarter-inch dimensions. Thickness and height variables are designated with 't' and 'h' specifications alongside maximum height limitations of one foot six inches and two feet zero inches. Concrete fill conditions are cast into the deck flutes, and number four epoxy anchors may be used in lieu of number four hooked dowels at the contractor's option provided required clearances are maintained.
CONDITION WHERE VERT. REINF. DOES NOT ALIGN W/ DOWN FLUTE CONDITION WHERE VERT. REINF. ALIGNS W/ DOWN FLUTE #4 @ 12" O.C. CTR. ON DOWN FLUTE. 3/4" CLR. 2 1/4" CLR. #4 @ 12" O.C. 2 1/4" CLR. #4 @ 12" O.C. CTR. ON DOWN FLUTE. 3/4" CLR. #4 @ 12" O.C. #4 CONT. #4 CONT. 1' - 6" MAX. ' h ' S.A.D. NOTE : #4 EPOXY ANCHORS MAY BE USED IN LIEU OF #4 HOOKED DOWELS AT CONTRACTOR'S OPTION. THE CLEARANCES ILLUSTRATED ABOVE MUST BE MAINTAINED. S.A.D. ' t ' S.A.D. ' t ' S.A.D. ' t ' S.A.D. ' t ' FOR 't' ≤ 8" FOR 't' > 8" FOR 't' ≤ 8" 1' - 6" MAX. "h" S.A.D. S.A.D. ' t ' FOR 'h' ≤ 3" ' h ' S.A.D. CAST W/ CONC. FILL FOR 'h' ≤ 3" FOR 't' > 8" S.A.D. ' t ' ' h ' S.A.D. CAST W/ CONC. FILL 2' - 0" MAX. 'h' S.A.D. MAX. 1' - 6"