A reinforced concrete basement wall extends from a mat foundation up to the Level 1 floor slab, incorporating intermediate parking garage floor slabs. The foundation detail features a concrete mat supporting the vertical wall with a roughened construction joint of one-quarter inch amplitude and a designated development length for vertical reinforcement. U-bars matching the vertical reinforcement tie the top of the wall into the Level 1 slab. Intermediate garage floor slabs connect to the wall with typical waterstops coordinated with architectural drawings. Vertical and horizontal reinforcing parameters are indicated as TBD.
201 LEVEL 1 0' - 0" 201 GARAGE P1 -14' - 6" 201 GARAGE P2 -25' - 6" SOG MAT SLAB U- BARS TO MATCH VERT, REINF TBD VEF TBD HEF SEE "TYPICAL SLAB ON GRADE ADJACENT TO WALL" 1/4 INCH AMPLITUDE ROUGHENED CJ, TYP ℄ WALL Ld SLAB SEE "TYPICAL SLAB CONNECTION TO BASEMENT WALL" TYPICAL WATERSTOP, SEE ARCH TYPICAL WATERSTOP, SEE ARCH TYPICAL WATERSTOP, SEE ARCH