A wide-flange column transfers load down to a wide-flange transfer beam through a column base plate and anchor bolts aligned with stiffener plates. The transfer beam connects to a supporting wide-flange column using a bolted shear tab connection. Additional web doubler plates are provided as required by the structural plan to reinforce the transfer beam web. The upper column offset is dimensioned with a minimum extension of three feet six inches from the supporting column centerline.
SECT TRANSFER DIM MIN EXTEND 3'-6" WEB DOUBLER PL AS REQD PER PLAN CL COL WF COL & BASE PL PER COL SCHED CL COL TRANSFER BM PER PLAN STIFF PL ES PER "TYP COL BASE PL, TYPE 3" DET COLUMN TRANSFER ≥3'-0" WF COL PER SCHED