This structural section details a concrete beam and adjacent slab step assembly with a construction joint and formsavers installed at the contractor's option. The concrete beam is reinforced with nine continuous number nine bottom bars, six continuous number nine top bars, nine continuous number nine bars, and number five stirrups spaced at six inches on center. The slab features a stepped transition detailed per the typical mild slab reinforcement standard. Grid lines R7 and G align with the cable net connection and the beam centerline respectively. Level one elevation is established per plan.
G R7 CL BM AT CL OF CABLE NET CONN (9) #9 BOT CONT #5 @ 6" STIRR, TYP (9) #9 CONT (6) #9 TOP CONT CJ AND FORMSAVERS AT CONTRS OPTION SLAB STEP PER "TYP MILD SLAB STEP REINF" DET PER CONC BM SCHED BM DEPTH NOTES: 1. REFERENCE DETAIL 1/S502 FOR ADDITIONAL INFORMATION NOT SHOWN. EL PER PLAN LEVEL 1 1/2" = 1'-0" 11 SECTION