This assembly connects a hollow structural section wind girt to a wide flange steel column using a three-eighths inch thick minimum center plate. The center plate is welded to the steel column with three-sixteenths inch fillet welds on both sides. The hollow structural section wind girt is secured to the center plate using three-quarter inch diameter through-bolts, with a one and one-half inch typical spacing. The assembly maintains a minimum one-half inch clearance between the wind girt and the insulated metal paneling system provided by others. Cold-formed steel studs are positioned adjacent to the assembly as specified by others.
Text on the drawing
A A C TYP 1 1/2" 1 1/2" TYP CFS STUDS BY OTHERS 3/4'' DIA. THRU BOLT 1'-4" x 0'-6" x 3/8" THK (MIN) PLATE 3/8"THK (MIN) CENTER PLATE 3/16 3/16 CENTER PLATE TO STEEL COL 3/16 3/16 TYP TYP 3/16 3/16 INSULATED METAL PANELING PER ARCH WIDE FLANGE STEEL COLUMN PER SCHEDULE HSS WIND GIRT PER ELEVATION A A MIN 1/2"