A concrete footing is thickened locally to maintain the required depth of top reinforcing steel where it conflicts with a pipe sleeve. The top reinforcement dips beneath a maximum six-inch diameter sleeve while maintaining minimum clearances of two inches above and one inch below the sleeve face. Rebar follows a six-to-one slope transition on each side of the obstruction with a twenty-four-inch typical lap splice. Reinforcement size and spacing are sized per plan.
6"Ø MAX. PIPE IN SLEEVE - SEE REINFORCEMENT - SEE PLAN TOP OF FTG. USE THIS DETAIL WHERE SLEEVE INTERFERS W/ TOP REINF. THICKEN FTG. TO MAINTAIN DEPTH OF TOP REINF. FACE OF REINF. FACE OF SLEEVE 2 S-155011 1" CLR. MIN. EQ. 2" MIN. CLR. EQ. 1 6 6 1 24" LAP, TYP. CONDITION III