A continuous wide-flange beam rests above a hollow structural section column, separated by a one-inch clearance space and a quarter-inch shim. The connection uses an L8x4x1/2 angle on each side of the column, featuring two one-and-a-half-inch vertical short slot holes fastened with two three-quarter-inch diameter A325 bolts at the bottom of the slots. Three-eighths-inch stiffener plates are welded to both sides of the beam web with three-sixteenths-inch welds on three sides. The seat angles are secured with typical five-sixteenths-inch welds.
L8x4x1/2 AT EACH SIDE 3/8" STIFF PL BOTH SIDES HSS COL SEE PLAN L8x4x1/2(LLV) TYP EA SIDE OF HSS W/(2) 1-1/2" VERT SHORT SLOT HOLES (2) 3/4"Ø A325 BOLTS AT BOTT OF VERT SLOT HOLES, TYP BEAM - SEE PLAN A-A A B A B B-B (AT OFFSET) BEAM SEE PLAN 3/16 3 SIDES SEE PLAN 1" CLR SPACE 1/4" SHIM 5/16 TYP TYP 1/2" MIN 1 1/2" 1 1/2" 2" 1 1/2" 1 1/2"