An interior new concrete slab-on-grade infill is placed against an existing slab-on-grade with a sawcut edge. Number 4 dowels at mid-depth of the existing slab are epoxy-anchored with six-inch embeds at twenty-four inches on center. Number 3 dowels at two feet zero inches with four-inch embeds are epoxy-anchored at eighteen inches on center typically along the perimeter. The new slab features number 4 reinforcing bars at eighteen inches on center each way with a minimum thickness of four inches. A continuous number 4 reinforcing bar is detailed at the thickened edge section.
(24" MIN) AS REQD MIN 4" (N) CONC SLAB TYP 6" MAX #4 @ 18"OC EA WAY SAWCUT (E) SOG AS REQD (E) SOG #3 x 2'-0" W/ 4" EMBED @ 18"OC W/ EPOXY TYP @ PERIMETER EQ EQ 2'-0" #4 CONT 1 1 1 1 #4 DOWEL @ MID-DEPTH OF (E) SOG W/ 6" EMBED @ 24"OC W/ EPOXY (E) SOG SOG & REINF PER PLAN MATCH B.O. (E) SOG