Buckling-restrained braces connect to a gusset plate positioned above a wide-flange beam. The gusset plate integrates with an interrupted concrete slab and reinforcing over a cross-laminated timber deck. Shear dowels and slab reinforcement are provided per plan, with slab reinforcement welded through the gusset plate using E80 electrodes. A three-inch minimum clearance is maintained between the brace gusset and the concrete assembly. The wide-flange beam and buckling-restrained braces are sized per plan.
NOTES: CL BRACE CL BRACE CL OF WF BM INTERRUPTED SLAB REINF WELDED THRU GUSSET PL, TYP. (USE E80 ELECTRODE) W.P. BRBF BM PER PLAN CONC SLAB & REINF PER PLAN BRB PER PLAN BRB PER PLAN BRB GUSSET BY OTHERS 3" MIN CLR SHEAR DOWELS PER PLAN CLT DECK PER PLAN