A reinforced concrete slab bears on a structural steel beam with a 12 gauge edge form at the perimeter. Two continuous number 4 reinforcing bars are provided with a standard 90-degree hook at the slab edge, extended one foot six inches at outside corners and three feet past inside corners. A minimum two-inch clearance is maintained at the beam flange bearing interface. A field weld symbol specifies a 1/8-inch weld with a 12-inch pitch.
1/8 2-12 12" GA. EDGE FORM SLAB REINF., PROVIDE STD. 90° HOOK AT SLAB EDGE (2) #4 CONT. PROVIDE 1'-6" HOOK AT OUTSIDE CORNERS OF SLAB EXTEND BARS 3'-0" PAST INSIDE CORNERS OF SLAB 6" MAX. - SEE ARCH. 2" MIN. 2" MIN.