A hollow structural section beam connects to a supporting member at the wall face using a three-quarter-inch plate welded with quarter-inch fillet welds top and bottom. The connection is secured with two three-quarter-inch diameter ASTM A325 bolts. A one-half-inch cap plate is welded to the beam end with quarter-inch welds. Additional plates and beams are sized per plan.
HSS BEAM PER S-113B 1/4 1/4 3/4" PL Ox 1" 1/2" CAP PL BM PER PLAN 1/4 3" (2) 3/4" DIA A325 BOLTS 2 SS-520 WALL FACE 1/4 TOP & BOTTOM 1/4 1/4 3/4" PL 1 1/2" 1 1/2" Ox BM PER PLAN, TYP PL PER 1/SS-520, TYP HSS BM PER S-113B WALL FACE PL & BOLT PER 1/SS-520, TYP
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.