A steel beam supports a metal roof deck framed against a supporting steel beam member. A web stiffener is provided per general structural notes on the supporting column or beam web. A one-half-inch offset dimension is maintained from the beam centerline. Roof edge overhangs greater than twelve inches require reference to detail E5 on sheet S701.
STL BM L 1/2" STL BM BM NOTE: FOR ROOF EDGE OVERHANG GREATER THAN 12", SEE DET WEB STIFF, SEE GSN MTL ROOF DECK MTL ROOF DECK A1 S301 E1 S701 / (E5 S701)